Langsung ke konten
Langsung ke konten

Services

Calibration Laboratory

Integrated Waste Management and Laboratory Unit – University of Jember

KAN accredited · SNI ISO/IEC 17025:2017 · LK-180-IDN · valid until 2027

Calibrated instruments mean results you can trust. The UPA PL2T Calibration Laboratory has been accredited by KAN since 2014 under number LK-180-IDN, calibrating mass, volume, temperature and pressure instruments for laboratories, hospitals, industry and small businesses.

30calibration services
2014KAN accredited since
17025SNI ISO/IEC 17025:2017

Calibration

Standard weights

Per instrument. Accredited.

Electronic balances, 0–4 decimals

Per instrument. Accredited. 5 decimals also available.

Single-channel micropipettes

Per instrument. Accredited. Multichannel available.

Volumetric flasks / pipettes

Per instrument. Accredited. Also burettes and measuring cylinders.

Thermometers 0–200 °C

Per instrument. Accredited.

Thermohygrometers

Temperature, or temperature and humidity.

Ovens, incubators, chillers, water baths

Per measuring point (temperature enclosure calibration).

Sphygmomanometers

Per instrument. Accredited.

The fee for each service is listed in the Fee List. See also the instruments listed under Laboratory Equipment.

Accredited scope

Mass

Standard weights 1 mg – 20 kg and electronic balances up to 500 kg.

Volume

Volumetric flasks, volumetric and graduated pipettes, burettes, measuring cylinders, and micropipettes 20–1,000 µL.

Temperature and humidity

Thermohygrometers, indicating thermometers −27 °C to 160 °C, and ovens, incubators, refrigerators and chillers (3–190 °C).

Pressure

Analogue sphygmomanometers 50–250 mmHg, for University of Jember units only.

Methods follow KAN, CSIRO, OIML R 111, JIS and SNSU guidelines. The uncertainty for each range is listed in the certificate annex.

Accreditation certificate

KAN accreditation certificate LK-180-IDN for the Calibration Laboratory of the University of Jember, valid 29 August 2022 to 28 August 2027

LK-180-IDN

The National Accreditation Committee of Indonesia (KAN) recognises the Calibration Laboratory of the University of Jember as competent in applying SNI ISO/IEC 17025:2017. The scope was extended by a supplement of 22 April 2026 to standard weights, micropipettes and indicating thermometers.

Issued
29 August 2022
Valid until
28 August 2027

Scope annex (PDF) 2026 supplement (PDF)

Calibration Laboratory

Location and contact

Calibration Laboratory, Mas Soerachman Building, ground floor, Jl. Kalimantan No. 37, Tegalboto Campus, Jember

kalibrasi@unej.ac.id

Calibration desk +62 856-4922-7179

Calibration at your site

For instruments that are large or must not be moved, such as analytical balances, ovens, incubators and chillers, our calibration officers come to where the instrument is used.

Payment

An invoice is issued after calibration. Pay by QRIS, virtual account or cash, and we issue a receipt.

How it works

  1. RequestBy letter, via the calibration desk on WhatsApp, or in person.
  2. Instrument receivedBring or send the instrument to the laboratory, or our officers come to your site.
  3. Request reviewFill in the request review form; measuring points and schedule are confirmed.
  4. Calibration and certificateCalibration against traceable standards; the certificate is issued about 14 working days after the instrument is received.
  5. Handover and paymentCollect the instrument and certificate, fill in the satisfaction survey, then pay by QRIS, virtual account or cash.

Service standards

Who can use this service
Laboratories, universities, hospitals, industry, small businesses and agencies that use measuring instruments.
Requirements
Submit a request by letter, via the calibration desk on WhatsApp (+62 856-4922-7179), by e-mail to kalibrasi@unej.ac.id, or in person at the Calibration Laboratory, then fill in the request review form.
Fees
According to the Fee List currently in effect.
Turnaround time
The calibration certificate is issued about 14 working days after the instrument is received.
Output
Calibration certificate.

Frequently asked questions

Which instruments can you calibrate?

Standard weights, electronic balances up to 500 kg, volumetric glassware, micropipettes, thermometers, thermohygrometers, ovens, incubators, refrigerators, chillers, water baths, furnaces, autoclaves, sphygmomanometers, pressure gauges, pH meters and turbidity meters.

Can your officers come to us?

Yes, for instruments that are large or must not be moved, such as analytical balances, ovens, incubators and chillers. Contact the calibration desk to schedule a visit.

Are all services accredited?

The mass, volume, temperature and humidity, and pressure scopes are accredited to SNI ISO/IEC 17025:2017 (LK-180-IDN); details are in the certificate annex. Sphygmomanometer calibration is for University of Jember units only.

How much does calibration cost?

The fee per instrument and for the certificate is listed in the Fee List.

Ready to start?Tell us about your samples and needs. We will help you choose the right method.